BroadPort 550 SMPTE 8-Port Rackmount Interface
Part Number: 55130-0
The BroadPort 550 controller is connected to the 1U 19" passive rack interface via a SCSI cable (provided). The interface is ideal for where rack space is limited; it is only 50mm deep. DB9 female connectors allow easy attachment of broadcast standard peripherals.
System Specifications
Hardware
- Number of Ports8
- EnclosureBlack Finished Steel
- Installation MethodRack Mountable
- Dimensions 16.3" x 2.2" x 1.7"
- Product Weight 17.5 oz.
Electrical Specifications
- ESD Surge Protection Provides minimum of 15KV protection for all serial lines.
Environmental Specifications
-
Air temperature
- System On 0 to 60° C
- System Off -20 to 85° C
-
Operating Humidity (non-condensing)
- System On 8 to 80%
- System Off 20 to 80%
- Altitude 0 to 10000 Feet
- Heat Output 4.81 BTU/Hr
- MTBF (Mean Time Between Failures) 30 years
Serial Communications
- Connector Type DB9F, SMPTE 207M
- Supported Standards RS-422, SMPTE
- Baud Rate 50 to 230.4 Kbps
Export Information
- Packaged Shipping Weight 1.96 lbs
- Package Dimensions 23.5" x 6.75" x 4.75"
- UPC Code 7-56727-55130-0
- Schedule B Number 8471.80.1000
Device Drivers
- Linux
- Microsoft® Windows NT
- Microsoft® Windows Vista tm
- Microsoft® Windows® 2000
- Microsoft® Windows® XP
Regulatory Approvals
-
Emissions
IEC 61326-1/ EN61326 Emissions standard for electrical equipment for measurement, control and laboratory use
EN55022 Class B Emissions Standard for domestic and light industrial environments
EN55011 Class B Emissions Standard for ISM Light Industrial
CISPR-22
FCC Part 15 Subpart B
Class B limit
-
Immunity
IEC61326-1/EN61326 Immunity standard for electrical equipment for measurement, control and laboratory use
IEC 1000-4-2/ EN61000-4-2 ESD Requirements
IEC 1000-4-3/ EN61000-4-3 Radiated Susceptibility
IEC 1000-4-4/ EN61000-4-4 Electrical Fast Transient Burst Requirement
IEC 1000-4-5/ EN61000-4-5 Surges Requirements
IEC 1000-4-6/ EN61000-4-6 Conducted Susceptibility
IEC 1000-4-11/ EN61000-4-11 Voltage Dips and Interruptions
-
Safety
IEC60950/EN60950
CSA C22.2 No. 60950/UL60950 Third Edition - Other Regulatory Approvals European Standard: 2002/95/EC Directive (RoHS)
- BroadPort 550 SMPTE 8 Port Interface
- Loopback Plug
- Mounting Brackets, Washers, Nut, & Screws
- Software/Documentation CD
Product Support and Service Information
Sales Support
Call +1.763.494.4100, or e-mail sales@comtrol.com
Technical Support
All Comtrol products come with easy-to-use documentation on a CD. For technical assistance, our U.S.-based technical support team is only a phone call away.
Call +1.763.494.4100, or submit your question online, or visit our forum .
Warranty
Comtrol offers a 30-Day satisfaction guarantee and a 5-year limited warranty on all BroadPort 550 family products! Extended Warranty Available.