DeviceMaster ® PNIO-2402

The DeviceMaster PNIO brings plant floor device visibility by enabling communication between factory floor devices and PLC controllers.


Product Name Change Notification

Part Number: 99544-9

PortVision DXweb


Engineering Drawing

Download Specifications
 

The DeviceMaster UP provides the following communication modes:

  • EtherNet/IP™ to Serial or Ethernet TCP/IP
  • PROFINET IO to Serial or Ethernet TCP/IP
  • Modbus/TCP to Serial or Ethernet TCP/IP
  • Modbus/TCP to Modbus/RTU
  • Modbus/TCP to raw serial data
  • Modbus/RTU Device (Auto Locate and Auto Route)
  • TCP/IP Socket Communication

The easy-to-use configuration and Industrial Ethernet protocol options makes upgrades for plant floor global visibility faster and more economical than ever before. The DeviceMaster UP enables managers to leverage legacy devices and boost ROI, while reducing PLC programming and maintenance costs with simplified PLC interfaces.

Highlights

  • DIN-rail mounting and screw terminal connections
  • Wide operating temperature ranges (-37º C to 74º C)
  • Surge protection for serial ports
  • Variable power input
  • Support for EtherNet/IP™, PROFINET I/O, Modbus/TCP, and TCP/IP(sockets)
  • Dual Ethernet ports for daisy chaining network connections between multiple units
  • Two serial ports with secure screw terminal connectors
  • DualConnectPlus™ technology
  • SSL & SSH management, SSL serial data stream encryption
 

Only the DeviceMaster PNIO Industrial Ethernet gateway offers a solution that configures in minutes via the web, allowing you to support PROFINET IO. The DeviceMaster PNIO provides an RS-232, RS-422 or RS-485 software-selectable serial connection to an Industrial Ethernet network.

Supported PLCs: Siemens SIMATIC S7-300, S7-400, S7-1200, S7-1500, and ET 200 CPUs that support the extended PROFINET diagnostics.

UP1P2P2E
Includes:
  • DeviceMaster PNIO-2402
 
Hardware
  • Bus Interface Specification 10/100BASE-T
  • Memory
    • SDRAM 8 MB
    • Flash 4 MB
  • Enclosure UL94-V0 PLASTIC
  • Installation Method DIN Rail (35mm)
  • LED Indicators ETHERNET ACTIVITY, ETHERNET LINK, and STATUS
  • Dimensions 4.37" x 3.9" x .89"
  • Product Weight 7.5 oz
Electrical Specifications
  • DC Input Voltage 5-30V
  • Current Consumption +24VDC 80 mA
  • Power Consumption (max) 2.0 W
  • ESD Surge Protection Minimum 25KV for all serial lines. All ehternet components are rated to 1.5KV magnetic surge protection.
Environmental Specifications
  • Air temperature
    • System On -37° C to 74° C
    • System Off -40° C to 85° C
  • Operating Humidity (non-condensing) 5% to 95%
  • Altitude 0 to 10000 Feet
  • Heat Output 6.6 BTU/Hr
  • MTBF (Mean Time Between Failures) 45.66 Years

Serial Communications

  • Connector TypeScrew Terminal Blocks
  • Number of Ports2
  • Software Interfaces RS-232
    RS-422
    RS-485 2-Wire
    RS-485 4-Wire Master
    RS-485 4-Wire Slave
  • Baud Rate 300 bps to 230.4 Kbps
    • Receive Buffer 1024bytes
    • Transmit Buffer 256bytes
  • Serial Data Control
    • Data Bits5, 6, 7 or 8
    • ParityNone, Even, Odd, Mark, Space
    • Stop Bits*1, 1.5 (with 5 data bits), or 2
    • Flow ControlNone, RTS/CTS, Xon/Xoff, Half-Duplex
  • *Stop bit 1.5: Supported only when used with 5 data bits
Ethernet Specifications
  • Network Protocols ARP, BOOTP, DHCP, HTTP, ICMP, Ping, RARP, RFC 1006 (ISO over TCP), RFC 2217, SNMP (MIB-II), TCP/IP, Telnet, TFTP, and UDP socket services
  • Connector TypeRJ45F Auto MDI/MDI-X
  • Number of Ports2
Export Information
  • Packaged Shipping Weight 1.04 lbs
  • Package Dimensions 9.25" x 2.5" x 7.25"
  • UPC Code 7-56727-99544-9
  • Country of Origin USA
  • ECCN 5A991
  • Schedule B Number 8471.80.1000
Regulatory Approvals
  • Emissions FCC PART 15 SUBPART B
    CLASS A LIMIT
    AS/NZS CISPR 22
    European Standard EN55022
    Canadian EMC Requirements
    ICES-003
  • Immunity European Standard EN55024
    IEC 1000-4-2/EN61000-4-2: ESD
    IEC 1000-4-3/EN61000-4-3: RF
    IEC 1000-4-4/EN61000-4-4: FAST TRANSIENT
    IEC 1000-4-5/EN61000-4-5: SURGE
    IEC 1000-4-6/EN61000-4-6: CONDUCTED DISTURBANCE
    IEC 1000-4-8/EN61000-4-8: MAGNETIC FIELD
    IEC 1000-4-11/EN61000-4-11: DIPS AND VOLTAGE VARIATIONS
  • Safety IEC 60950/EN60950
    CSA C22.2 No. 60950/UL60950 Third Edition
  • Other Regulatory Approvals European Standard: RoHS 2 Compliant under CE
    NEMA TS2 COMPLIANT
 
Find a Distributor

» Industrial Distributors
» North American Distributors
» International Distributors

Pre-Sales Questions

Comtrol's Pre-sales Team
For sales questions or to locate a reseller near you.

+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
sales@comtrol.com

Comtrol's Industrial Automation Sales
For sales questions or to locate an industrial distributor near you.

+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
sales@comtrol.com


 
Documentation
DocumentDescriptionDownload File
DeviceMaster ® PNIO-2402 User GuideContains detailed installation procedures and configuration information.
Product Support and Service Information
Sales Support

Call +1.763.957.6000, or e-mail sales@comtrol.com